Optimizing plate working length and screw configuration for femoral shaft plate fixation: a finite element analysis under different bone quality scenarios - PubMed
8 days ago
- #Finite element analysis
- #Femoral fracture
- #Bone quality
- Study focuses on optimizing plate working length and screw configuration for femoral shaft plate fixation.
- Utilizes finite element analysis under different bone quality scenarios.
- Keywords include Femoral fracture, Finite element analysis, Strain, Stress, and Working length.
- Ethics approval obtained from National Taiwan University Hospital with a waiver for retrospective data use.
- No competing interests declared by the authors.
- References include studies on femoral shaft fractures, treatment options, and outcomes in different regions.